Sunway Machinery ManufacturingMANUFACTURER
24-Hour Information Hotline:+86-13386259279
Popular keywords: B. Zj -IV intelligent high-speed hose shoulder injection machine|B.GLS-III automatic soft control pipe machine|B. Kfx-ii hose opening and sealing screw (shoot) cap machine|B.GFN-100 filling and sealing machine
Your location: Homepage >News >Company news

Hotline

+86-13386259279

Common problems and solutions of automatic capping machine

Author: click:1714 Release time:2021-02-22

With the gradual strictness of packaging and the continuous change of packaging, we also clearly put forward higher requirements for the capping machine. The working pressure dimensions of the capping machine are strict. From simple manual capping to fully automatic capping of mechanical equipment, high, medium and low gears and other commodities at different levels meet the customer satisfaction of different capping machines. Decapping glass bottles of different materials.


The pursuit of perfect stability of machinery and equipment, the development of automation technology level of machinery and equipment, so that our screw capping can serve you more. Increase the trouble free control time of all machines and equipment. So that our capping machine is more commonly used in the packaging production line. When we choose capping machine, we choose large manufacturers and are optimistic about the quality of goods.


Today, I summarized four common problems and solutions of automatic capping machine:


1. The control switch is invalid due to the drift of the toggle switch or photoelectric switch. Such a common fault can adjust the working part of the power switch or photoelectric switch, or replace the power switch.


2. The operation current caused by the short-circuit fault of electric stage winding resistance and casing and the short-circuit fault of electrical wiring and wire connector is nothing more than the amount of current. On the one hand, this common fault can detect the motor, on the other hand, check whether the relevant wires are loose


3. The acceleration time setting of capping machine is too short and the high-voltage electric shock volume exceeds the volume of soft starter. The common fault of over current flow during acceleration can moderately increase the F001 value setting time, and the electric volume can not be changed casually.


4. The operating voltage is too high due to the excessive change of power supply voltage. It can be easily handled by inputting the switching power supply into the measuring and adding series reactor or moderately reducing the power supply voltage.